$10
The ZM303 is an everyday indicator available in aluminum or IP69K stainless steel, with a choice of industry leading displays.
Click For other scale indicators Products
- Features
- Numeric keypad with assignable function keys for more complex processes.
- Hi-vis display to improve productivity.
- Adaptable to a variety of industrial environments.
- Protective aluminum enclosure for office environments.
- A robust IP69K certified stainless steel enclosure for harsh indoor or outdoor use,
- or a stainless steel panel mounts design for control room applications.
- SpecificationsOperating Applications :
General weighing, accumulation, check weighing, counting, peak measurement, batching and remote displayUnit of Measure:
Six, configurable (Pounds, Kilograms, Ounce, Gram, Pound/Ounce, Custom)Capacity Selections:
9,999,999 with decimal located zero to five placesIncremental Selections:
Multiples and sub-multiples of 1, 2, 5Programmable Selections :
Zero range, motion detection, automatic zero tracking, five point linearizationTime and Date:
Battery backed up time/date/year (12 hr or 24 hour format)
Calibration:
Two to five points storedAnalog to Digital Measurement:
Rate 80 HzInternal Resolution:
53,687,100 counts per mV/V per secondDigital Filtering :
Harmonizer filtering with adaptable constant and thresholdSelf Diagnostics :
Display, keys, inputs, outputs, serial port - TechnicalINPUT/OUTPUT
Remote Inputs :
Three logic level inputs for Zero, Print, Tare, Units or F1Standard Outputs :
Three set point outputs, open collector designSerial Ports :
Two serial ports: – Comm 1 RS232 full duplex – Comm 2 RS232 full duplex Or – Comm 1 RS232 full duplex with handshaking – Comm 2 Not available Programmable serial response to ASCII input SMA protocol, broadcast, enquireUSB Host :
Printer Connect USB flash memoryEthernet:
Ethernet IP, FTP, Modbus TCP and DHCPOptional :
Analog output Current Loop/RS485/RS422 USB Device Internal Wireless 802.11b/g
ELECTRICAL
Power Requirements :
Line voltage: 90-264 VAC (110-240 VAC nominal), frequency 50 or 60 Hz, 12 to 36 VDC Power consumption: estimated at 200 mA at 12 VDC for one weight sensor and 250 mA at 12 VDC for six weight sensors.Excitation :
5 VDC, short circuit protected Supports up to six 350 ohm weight sensors 4 or 6 conductors with sense leads Detachable plug connectorsAnalog Signal Input Range:
-1 m/V/V to 5 mV/VAnalog Signal Sensitivity:
µV/V/divisions minimum 0.5 µV/V/divisions recommendedCircuitry Protection:
RFI, EMI and ESD protection