$10

choose rice lake's cw-90x over/under washdown checkweigher for heavy washdown environments and haccp requirements

For all of your industrial scale indicators needs, give us a call at 972-287-0101. Our team of experts is ready to serve!

  1. Features
    • Piezo keypad consisting of ZERO, UNITS, PRINT, TARE, OVER, UNDER, ID, TARGET, ENTER, MENU, POWER
    • 304 stainless steel, IP69K rated indicator
    • PreVent™ breather vent
    • Storage for up to 50 IDs
    • Unit of measure: kg, gm, lb, oz, lb/oz (lb/oz is not Legal for Trade)
    • High-intensity LED display
    • Battery-backed time and date
    • Two full-duplex RS-232 serial ports
    • Configurable print formats
    • Audit trail tracking
    • Optional communications: Ethernet, USB or fiber-optic
    • Four configurable Digital I/O
    • Reflash memory to upgrade the firmware
    • Auto print capability
    Scale:
    • IP69K, stainless steel, hermetically sealed load cell
    • 304 stainless steel
    • Five-point overload protection
  2. Specifications

    Power-AC:
    Line voltages:
    115/230 VAC
    Frequency:
    50/60 Hz

    Power Consumption:
    1.5 A at 115 VAC (8 W),
    0.75 A at 230 VAC (8 W)

    Measurement Rate:
    960, 480, 240, 120, 60, 30, 15, 7.5 per second

    System Linearity:
    ±0.01% full scale

    Digital I/O:
    Four channels on CPU board

    Circuit Protection:
    RFI, EMI, ESD protection

    Display:
    Large 0.8 in, 14-segment, six-digit high-intensity red
    LED display

    Status Annunciators:
    Designators for %, kg, gm, lb, oz, center of zero, G/B, N, T, PT, neg, motion

    Operating Temperature:
    Legal: 14º F to 104º F (-10º C to 40º C)

    Rating/Material:
    IP69K, stainless steel

    Display Resolution:
    100,000 graduations maximum

    Load Cell:
    IP69K, stainless steel, hermetically sealed

    Warranty:
    Three-year limited warranty

    Approvals:
    NTEP CC 08-092, Class III/IIIL 10,000 d
    Measurement Canada AM-5710, Class III 10,000 d
    OIML R76/2006-GBI-10.02
    TC GB-1385
    TAC UK2900
    UL and CUL listed
    CE marked
    Scale:
    NTEP CC 95-072, Class III 5,000 d
    Measurement Canada AM-5082, Class III 5,000 d
    NSF

  3. Get a Quote